Weather station setup:

*Later changed to measure soil temprature at 0.01 m bellow ground (see metadata). **Installed at a later date (see metadata)

The sampling interval and storing is 1 minute. Data are acquired every hour over LTE.

The power supply is an important component of the weather station: photovoltaic modules and wind turbine are mounted on separated mast – 4 meters distance from weather station to prevent interference with measured parameters.

Main data parameters:

InstrumentNameUnitDescription
VUE10AirTC°celciusAir Temperature
VUE10RHPercentageRelative Humidity
05103WindDirdegreesWind Direction
05103WS_msmeter/secondWind Speed
S2-141PARumol/m^2*sPhotosynthetically Active Radiation
S2-141FAR_REDumol/m^2*sFar Red Light
T107_C*Deg C°celciusSoil temp 0.01m BGL
SP-700KglobW/m^2Global Solar Radiation
SP-700KrefW/m^2Diffuse Solar Radiation
CS655*VWC_Avgm^3/m^3Volumetric Water Content (7-20 cm BLG)
CS655*EC_AvgdS/mElectrical Conductivity (7-20 cm BLG)
CS655*T_Avg°celciusSoil Temperature (0-7cm BLG)
*Notable changes, see event log

Event log:

Date and Time [YYYY-MM-DD HH:MM:SS]Event DescriptionResponsible
2021-05-04 06:56:00Start timeUNIS Logistics
2021-09-02 15:00:00CS655 Soil Water Content Reflectometer installed. flush with soil, 2m from WSSimen Hjelle (SH)
2021-09-21 16:00:00107 Thermistor probe changed to 0.01 m bellow soil from 0.1 m air temp SH
2021-12-14 12:00:00Wind turbine released. Soil temp probe T107 protected with stone. Time lapse camera startSH, Simone Lang (SL)
2022-08-02 13:20:00Fixed soil temperature probe T107 (Got exposed to air, now it is bellow ground)SH
2022-09-10T107 and CS655 out of service. Reindeer.SH

Contact:

Contact person: Simone Lang